Conference Dates
July 1-6, 2007
First Page
138
Abstract
Fouling caused by sweet cheese whey and reconstituted whey powder solutions was studied in a Centritherm evaporator, the behaviour being estimated by measuring the change in the overall heat transfer coefficients with the time. It was found that there was no fouling detectable for the reconstituted whey powder solution. For sweet cheese whey, the fouling rate was linked strongly with the evaporating temperature and temperature difference. Visual observation showed that the deposit layer on the evaporator surface was very thin and soft, and like the type A milk deposit described by other investigators. A high velocity of liquid film delayed the formation of deposit on the surface. Some interactions between the evaporation temperature, feed flow rate, rotating speed and temperature difference are discussed. The fouling is caused by denaturation of bovine serum albumin in a second order rate reaction.
Recommended Citation
R. S. Jebson, H. Chen, and O. H. Campanella, "FOULING IN A CENTRITHERM EVAPORATOR WITH WHEY SOLUTIONS" in "Heat Exchanger Fouling and Cleaning VII", Hans Müller-Steinhagen, Institute of Technical Thermodynamics, German Aerospace Centre (DLR) and Institute for Thermodynamics and Thermal Engineering, University of Stuttgart, Germany; M. Reza Malayeri, University of Stuttgart, Germany; A. Paul Watkinson, The University of British Columbia, Canada Eds, ECI Symposium Series, (2007). https://dc.engconfintl.org/heatexchanger2007/19