In order to develop design recommendations for column-foundation connection assembled by post-tensioning in seismic regions, cyclic loading tests were carried out on 14 test units simulating such kind of connections under earthquake loading. The tests were consisted of two series: Series A was mainly for comparison between precast reinforced and precast prestressed concrete column-foundation connections, and Series B for investigating differences between test units with grouted and ungrouted tendons. The main experimental parameter other than the above was an axial load level.
Recommended Citation
Minehiro Nishiyama and Fumio Watanabe, "Seismic Performance of Precast Column-Foundation Connection Assembled by Post-Tensioning" in "Advanced Materials for Construction of Bridges, Buildings, and Other Structures III", Vasant Mistry, P.E., Office of Bridge Technology, Federal Highway Administration, USA; Dr. Atorod Azizinamini, Ph.D., P.E., Civil Engineering Department, University of Nebraska, USA; John M. Hooks, P.E., Office of Infrastructure Research & Development, Federal Highway Administration, USA Eds, ECI Symposium Series, Volume P05 (2003). https://dc.engconfintl.org/advanced_materials/5