Title
Study of Standpipe and Loop Seal Behavior in a Circulating Fluidized Bed for Geldart B Particles
Conference Dates
May 1-5, 2011
Abstract
The loop seal aeration effect on the supply side has been studied through small scale CFB experimentation. Parameters affected include inventory allocation and entrainment. The gas velocity in the standpipe is influenced by loop seal aeration and riser velocity. Variation in slugging behavior above and below solid downflow velocity of 0.025 m/s is analyzed and discussed here.
Recommended Citation
Heiko Dieter, Alexander Charitos, Ajay R. Bidwe, An Wei, and Mariusz Zieba, "Study of Standpipe and Loop Seal Behavior in a Circulating Fluidized Bed for Geldart B Particles" in "10th International Conference on Circulating Fluidized Beds and Fluidization Technology - CFB-10", T. Knowlton, PSRI Eds, ECI Symposium Series, (2013). https://dc.engconfintl.org/cfb10/75