The 12th International Conference on Fluidization - New Horizons in Fluidization Engineering
CANNOT FIND FILE: date.inc - CANNOT FIND FILE: location.inc
Editors: | CANNOT FIND FILE: editors.inc |
Conference Dates
May 13-17, 2007
Abstract
In this paper, Electrical Capacitance Volume Tomography (ECVT) is used to study a gas-solid fluidized bed system of .1 m ID. The interior flow structures (including the dynamic bed expansion, bubble/void breakage and particle movement) and the charge distribution in a gas-solid fluidized bed are illustrated based on the 3D images obtained from the ECVT.
Recommended Citation
B. Du, Q. Marashdeh, W. Warsito, A.-H. A. Park, and L S Fan, "Development of Electrical Capacitance Volume Tomography (ECVT) and Electrostatic Tomography (EST) for 3D Density Imaging of Fluidized Bed System" in "The 12th International Conference on Fluidization - New Horizons in Fluidization Engineering", Franco Berruti, The University of Western Ontario, London, Canada; Xiaotao (Tony) Bi, The University of British Columbia, Vancouver, Canada; Todd Pugsley, University of Saskatchewan, Saskatoon, Saskatchewan, Canada Eds, ECI Symposium Series, (2007). https://dc.engconfintl.org/fluidization_xii/57